EVIの暖房及び冷却のヒート ポンプ
技術的なparamater:
モデル | KFXFC-009SEI | KFXFC-014SI | KFXFC-018SI | KFXFC-020UII | DKFXFC-032UII | ||
包囲された臨時雇用者。範囲 | ℃ | -30~+43 | -30~+43 | -30~+43 | -30~+43 | -30~+43 | |
電源 | / | 220V 1N~50Hz | 220V 1N~50Hz | 220V 1N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | |
感電の証拠の等級 | / | クラスI | クラスI | クラスI | クラスI | クラスI | |
保護等級 | / | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
冷却capacity/COP | KW/- | 7.3/2.8 | 12.0/3.0 | 14.5/2.6 | 27.0/2.8 | 27.0/2.8 | |
低温暖房(A-12W41) /COP | KW/- | 5.1/2.2 | 9.2/2.4 | 11.0/2.3 | 20.0/2.3 | 20.0/2.3 | |
正常な温度の暖房(A7W45) /COP | KW/- | 8.8/3.3 | 14.4/3.7 | 18.4/3.6 | 32.0/3.6 | 32.0/3.6 | |
警察官 | A7W35а/COP | KW/- | 9.4/4.1 | 14.5/4.5 | 18.5/4.3 | 33.0/4.3 | 33.0/4.3 |
A-7W45/COP | KW/- | 5.8/2.3 | 9.4/2.6 | 13.1/2.6 | 23.5/2.3 | 23.5/2.6 | |
A-15W45/COP | KW/- | 4.5/2.2 | 8.0/2.2 | 10.2/2.1 | 19.5/2.2 | 19.5/2.2 | |
A-20W45/COP | KW/- | 4.2/1.9 | 6.5/1.9 | 8.6/2.0 | 16.5/2.0 | 16.5/2.0 | |
評価される冷却の入力パワー | KW | 2.61 | 4 | 5.6 | 9.6 | 9.6 | |
低温の入熱力 | KW | 2.32 | 3.83 | 4.8 | 8.7 | 8.7 | |
最高。現在の働くこと | 20 | 32 | 40 | 25 | 25 | ||
圧縮機 | タイプ | / | スクロール | スクロール | スクロール | スクロール | スクロール |
量 | PCS | 1 | 1 | 1 | 2 | 2 | |
ファン モーター | 量 | PCS | 1 | 2 | 2 | 2 | 2 |
水収穫 | L/h | 1600 | 2500 | 2500 | 4600 | 4600 | |
冷却するタイプ/重量 | - /kg | R407c/2.2 | R407c/4.5 | R407c/5.0 | R407c/7.5×2 | R407c/4.0×2 | |
次元(W×D×H) | mm | 1087×435×901 | 1052×362×1346 | 1120×435×1355 | 1500×850×1750 | 1530×750×1370 | |
パッキング次元(W×D×H) | mm | 1230×500×1050 | 1160×540×1460 | 1230×540×1530 | 1600×950×1900 | 1650×850×1470 | |
騒音 | dB (A) | 54 | 58 | 56 | 65 | 65 | |
純重量 | kg | 70 | 140 | 172 | 350 | 350 | |
総重量 | kg | 80 | 150 | 185 | 380 | 380 | |
循環の管の直径 | インチ | G1」外的な糸 | G1 1/4"外的な糸 | G1.2」外的な糸 | G1.5」外的な糸 | G1.5」外的な糸 |
モデル | DKFXFC-032UII | KFXFC-045UII | KFXFC-065UII | KFXFC-075UII | KFXFC-090UMII | KFXFC-150UII | KFXFC-180UMII | ||
包囲された臨時雇用者。範囲 | ℃ | -35~+43 | |||||||
電源 | / | 380V 3N~50Hz | |||||||
感電の証拠の等級 | / | クラスI | |||||||
保護等級 | / | IPX4 | |||||||
冷却capacity/COP | KW/- | 27.0/2.8 | 35/3.0 | 53.0/3.0 | 65.0/3.1 | 70.0/2.8 | 130.0/2.8 | 140.0/2.8 | |
低温暖房 (A-12W41) /COP | KW/- | 20.0/2.3 | 26.0/2.3 | 37.5/2.5 | 41.0/2.5 | 55.0/2.4 | 82.0/2.5 | 110.0/2.4 | |
正常な温度の暖房(A7W45) /COP | KW/- | 32.0/3.6 | 43.5/3.6 | 63.0/3.9 | 73.0/3.9 | 90.0/3.6 | 146.0/3.9 | 180.0/3.6 | |
熱容量 | A7W35а/COP | KW/- | 33.0/4.3 | 45.0/4.3 | 65.0/4.5 | 75.0/4.5 | 92.0/4.3 | 150.0/4.5 | 185.0/4.3 |
A-7W45/COP | KW/- | 23.5/2.6 | 30.5/2.6 | 41.0/2.6 | 45.0/2.6 | 62.0/2.6 | 90.0/2.6 | 122.0/2.6 | |
A-15W45/COP | KW/- | 19.5/2.2 | 25.0/2.2 | 34.0/2.2 | 38.0/2.2 | 50.0/2.2 | 76.0/2.2 | 100.0/2.2 | |
A-20W45/COP | KW/- | 16.5/2.0 | 21.0/2.0 | 30.2/2.0 | 33.0/2.0 | 43.0/2.0 | 66.0/2.0 | 86.0/2.0 | |
評価される冷却の入力パワー | KW | 9.6 | 11.7 | 17.7 | 21 | 25 | 46.4 | 50 | |
低温の入熱力 | KW | 8.7 | 11.3 | 15 | 16.4 | 22.9 | 32.8 | 45.8 | |
正常な温度の入熱力 | KW | / | / | 16.2 | 18.7 | 25 | 37.4 | 50 | |
最高の働く流れ | 25 | 32 | 47 | 55 | 65 | 110 | 130 | ||
圧縮機 | タイプ | / | スクロール | ||||||
量 | PCS | 2 | 4 | ||||||
ファン モーター | 量 | PCS | 2 | 4 | |||||
最高。水温 | ℃ | 60 | |||||||
水収穫 | L/h | 4600 | 6000 | 9100 | 11200 | 12000 | 22400 | 24100 | |
冷却するタイプ/重量 | - /kg | R410a/4.0×2 | R410a/8.0×2 | R410a/12×2 | R410a/15×2 | R410a/15×2 | R410a/15×4 | R410a/15×4 | |
次元(W×D×H) | mm | 1530×750×1370 | 1500×850×1750 | 2100×1100×2000 | 2100×2060×2250 | ||||
パッキング次元(W×D×H) | mm | 1650×850×1470 | 1750×950×1900 | 2260×1360×2270 | 2230×2250×2400 | ||||
騒音 | dB (A) | 65 | 65 | 68 | 68 | 68 | 69 | 69 | |
純重量 | kg | 350 | 380 | 850 | 950 | 950 | 1900年 | 1900年 | |
総重量 | kg | 380 | 420 | 900 | 1000 | 1000 | 2000年 | 2000年 | |
循環の管の直径 | インチ | G1.5 "外的な糸 | G1.5 "外的な糸 | DN50フランジ | DN50フランジ | DN65フランジ | DN65外的な糸 | DN65外的な糸 |
世帯heating+の冷却の設置図表:
パッキング:
![]() | ![]() |
参照:
国:台湾、中国の中学校 モデル:KFXR-018 UII、KFXR-045UII 適用:国内熱湯 | 国:台湾、中国の家屋 モデル:KFXR-036UII、KFXR-900UII 適用:国内熱湯 |
![]() | ![]() |
国:北京、中国 モデル:KFXF-180 UII 適用:暖房の繁殖 | 国:Yunan、中国 モデル:/ 適用:アロエの乾燥 |
![]() | ![]() |