China Categories
English
Home /Other Electronic Components /

Stainless Flammability Test Apparatus LDQ Dielectric Tester 44 - 55 Drops / cm ³ Drip Size

Stainless Flammability Test Apparatus LDQ Dielectric Tester 44 - 55 Drops / cm ³ Drip Size

Brand Name:Kinte
Certification:Certificate of conformity of quality management system certification
Model Number:WH-8902A (LDQ)
Minimum Order Quantity:1set
Delivery Time:customized
Place of Origin:Guangdong,China (Mainland)
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: No.16 Yufeng Road, Shiling Town, Huadu District, Guangzhou City, Guangdong Province
Supplier`s last login times: within 36 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Stainless Flammability Test Apparatus LDQ Dielectric Tester 44 - 55 Drops / cm ³ Drip Size


Overview:

In the electrical products under the influence of moisture and impurity environment, live parts with


different polarities between the live parts and ground metal may cause insulation on the leakage,


the arc caused by electrical short-circuit or due to the discharge of the material Electric corrosion


damage, or even ignite lead to fire.


The tracking test is a destructive test of the insulation material used to simulate and assess the


relative tracking resistance of an insulator during an electric field and the presence of water


containing impurities at a specified voltage. For electrical and electronic products, household


appliances, solid electrical insulating materials and their products, such as: relay sockets, switch


cover, contactor body, etc ... ....


Standard: in line with international GB4207 and GB4706.1 standards in the "tracking test


method" requirement. Function with technical indicators: the use of rectangular platinum


electrode, the force on the sample of the two poles were 1.0 ± 0.05N. The applied voltage can be


adjusted between 100 ~ 600V (48 ~ 60Hz). When the short circuit current is 1.0 ± 0.1A, the


voltage drop will not exceed 10%. When the short circuit current is equal to or greater than 0.5A, ,


Relay action, cut off the current, indicating the test sample failed. Drop device can make drip


height of 30 ~ 40mm adjustable, drip size of 44 to 55 drops / cm ³. Dropping time interval 30 ± 5


seconds adjustable.


Features: The tester is divided into two parts: chamber and control box. Stainless steel or brass


is used for the shell and structure of the chamber. The electrode head is platinum (platinum), the


corrosion resistance of flue gas is accurate and the control system is stable and reliable. Outside


dimension (mm): 530 × 390 × 750 510 × 550 × 300.

China Stainless Flammability Test Apparatus LDQ Dielectric Tester 44 - 55 Drops / cm ³ Drip Size supplier

Stainless Flammability Test Apparatus LDQ Dielectric Tester 44 - 55 Drops / cm ³ Drip Size

Inquiry Cart 0