Double Coil 3/8" Aluminum alloy 4V320-10 5/2 way Pneumatic Solenoid Valves AIRTAC

Brand Name:AIRTAC
Certification:CE, ISO9001
Model Number:4V320-08 4V320-10
Minimum Order Quantity:10 pcs
Delivery Time:3 working days after receiving the customers' payment
Payment Terms:T/T,Western Union,Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China
Supplier`s last login times: within 23 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

AIRTAC Double Coil 3/8" Aluminum alloy 4V320-10 5/2 way Pneumatic Solenoid Valves


Model No: 4V320-08 4V320-10
Place of Origin: Zhejiang,China (Mainland)
Power: Pneumatic
Standard or Nonstandard: Standard

Pressure: Low Pressure
Structure: Pilot
Material: Alloy
Temperature of Media: Normal Temperature
Media: Gas
Brand Name: Airtac SMC ASCO
Valve type: 5 port 2 position
Lubrication: Not required
Temperature : -20~70°C
Orifice size: 30.0mm2
Material of body: Aluminum alloy
Fluid: Air


Specification:

Model4V310-08
4V320-08
4V330C-08
4V330E-08
4V330P-08
4V310-10
4V320-10
4V330C-10
4V330E-10
4V330P-10
FluidAir(to be filtered by 40pm fillter element)
ActingPiloted
Port sizeln=Out=Exhaust=1/4"ln=Out=3/8" Exhaust=1/4"
Orifice size25.0mm2
(Cv=1.40)
18.0mm2
(Cv=1.00)
30.0mm2
(Cv=1.68)
18.0mm2
(Cv=1.00)
Valve type5 port 3 position5 port 2 position5 port 3 position5 port 2 position
Operating pressure0.15-0.8MPa(21-114psi)
Proof pressure1.5MPa(215psi)
Temperature °C-20-70
Material of bodyAluminum alloy
LubricationNot required
Max.frequency4 cycle/sec3 cycle/sec4 cycle/sec3 cycle/sec
Weight4V310-08:310g 4V320-08:400g450g4V310-10:310g 4V320-10:400g450g


Drawings size:



No.ItemNo.ItemNO.Item
1Connector9Wear ring17Override spring
2Coil net10Bottom cover18Manual override
3Coil11Fixed screw19Spring holder
4Armature12Spool spring20Return spring
5Fixed plate13Bottom cover gasket21Side cover
6Piston14Spool O-ring22Springholder
7Pilotkit15Spool
8Body16Piston O-ring

Flow chart :


Photo details


Competitive Advantage

Our product featuresOur Services Guarantee:
1) Competitive price1) Prompt respond (Reply with 24 hours)
2) Good quality2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging3) Registration support.
4) Produce according to Customers’ instruction4) Photos/videos are available during production.
5) None delay shipment5) Loading inspection, and send loading photos before shipment.

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.


After-sale Service
We can provide a series of after-sale service, such as product introduction, mounting, debugging, technical support and so on.


The exhaust chamber volume of improved DMF pulse valve is increased. The permeability magnetic material of pulse valve is increased, and also, the materials of structure of diaphragm and pressure spring are improved, so that the exhaust volume of valve is increased to raise the magnetic strength and sensitivity as well as the element reliability and operation stability of pulse valve. Its service life will be greatly prolonged.